Zur Kurzanzeige

2019-07-23Zeitschriftenartikel
Comparison of VITEK 2, three different gradient strip tests and broth microdilution for detecting vanB-posotive Enterococcus faecium isolates with low vancomycin MICs
dc.contributor.authorKlare, Ingo
dc.contributor.authorBender, Jennifer K.
dc.contributor.authorKriebel, Nancy
dc.contributor.authorHamprecht, Axel
dc.contributor.authorGatermann, Sören
dc.contributor.authorWerner, Guido
dc.date.accessioned2026-08-31T10:28:05Z
dc.date.available2026-08-31T10:28:05Z
dc.date.issued2019-07-23none
dc.identifier.other10.1093/jac/dkz310
dc.identifier.urihttp://edoc.rki.de/176904/13876
dc.description.abstractObjectives In 2018, EUCAST issued a warning regarding unreliable results of gradient strip tests for confirming vancomycin resistance in enterococci. We compared the performance of various diagnostic standard and confirmatory tests to identify and determine vanB-type vancomycin resistance. Methods We analysed a collection of vanB-positive Enterococcus faecium isolates (n = 68) with low vancomycin MICs and compared the performance of VITEK® 2 (bioMérieux), broth microdilution and three gradient strip tests from different providers (Oxoid, Liofilchem and bioMérieux). For the latter we compared the standard procedure with a protocol with increased inoculum, a rich agar medium and a longer incubation time (‘macromethod’). Results The sensitivity of VITEK® 2 was 81% compared with 72% for broth microdilution and 61%–63% for the three gradient strip tests using standard conditions. The macromethod substantially improved the performance of all strip tests resulting in a sensitivity of 89%–96% after 48 h of incubation. Conclusions We recommend that EUCAST changes the present warning against the general use of MIC strips. When MIC strips are used to either exclude or confirm suspected vancomycin resistance in E. faecium, and a PCR is not available, the macromethod should be employed. For clinically relevant enterococci, where a rapid therapeutic decision is needed, a molecular test (e.g. PCR) should be favoured in order to save time and to further increase sensitivity.eng
dc.language.isoengnone
dc.publisherRobert Koch-Institut
dc.rights(CC BY-NC 3.0 DE) Namensnennung - Nicht kommerziell 3.0 Deutschlandger
dc.rights.urihttp://creativecommons.org/licenses/by-nc/3.0/de/
dc.subject.ddc610 Medizin und Gesundheitnone
dc.titleComparison of VITEK 2, three different gradient strip tests and broth microdilution for detecting vanB-posotive Enterococcus faecium isolates with low vancomycin MICsnone
dc.typearticle
dc.identifier.urnurn:nbn:de:0257-176904/13876-4
dc.type.versionupdatedVersionnone
local.edoc.container-titleJournal of Antimicrobial Chemotherapynone
local.edoc.container-issn1460-2091none
local.edoc.pages4none
local.edoc.type-nameZeitschriftenartikel
local.edoc.container-typeperiodical
local.edoc.container-type-nameZeitschrift
local.edoc.container-urlhttps://academic.oup.com/jacnone
local.edoc.container-publisher-nameOxford Academicnone
local.edoc.container-volume74none
local.edoc.container-issue10none
local.edoc.container-reportyear2019none
local.edoc.container-firstpage2926none
local.edoc.container-lastpage2929none
dc.description.versionPeer Reviewednone

Zur Kurzanzeige