Zur Kurzanzeige

2020-07-16Zeitschriftenartikel DOI: 10.1186/s12879-020-05234-w
External quality assessment (EQA) of Neisseria gonorrhoeae antimicrobial susceptibility testing in primary laboratories in Germany
dc.contributor.authorSelb, Regina
dc.contributor.authorJansen, Klaus
dc.contributor.authorEckardt, Matthias
dc.contributor.authorTamminga, Thalea
dc.contributor.authorDudareva, Sandra
dc.contributor.authorGassowski, Martyna
dc.contributor.authorGraeber, Ingeborg
dc.contributor.authorGuhl, Eva
dc.contributor.authorHeuer, Dagmar
dc.contributor.authorBuder, Susanne
dc.contributor.authorGORENET EQA study group
dc.date.accessioned2026-09-07T15:11:37Z
dc.date.available2026-09-07T15:11:37Z
dc.date.issued2020-07-16none
dc.identifier.urihttp://edoc.rki.de/176904/13905
dc.description.abstractWorldwide, an increase in antimicrobial resistance (AMR) of Neisseria gonorrhoeae has been observed. Until now, no protocol for an external quality assessment (EQA) has been available for Germany. The German gonococcal resistance network (GORENET) performed an EQA of primary laboratories in Germany in order to assess quality of antibiotic susceptibility testing, to gain information about laboratory procedures and to assess the impact of these procedures on test results. Methods Laboratories assessed drug susceptibility to cefixime, ceftriaxone, azithromycin, penicillin and ciprofloxacin for five N. gonorrhoeae strains, using their standard laboratory protocols. Minimal inhibitory concentrations (MICs) were compared to World Health Organisation (WHO) consensus results (or, if not available, reference laboratory results), while deviation by +/− one doubling dilution was accepted. Data on laboratory procedures were collected via a standardised questionnaire. Generalized linear models and conditional inference trees (CTREE) were used to assess relationships between laboratory procedures and testing outcomes. Results Twenty-one primary laboratories participated in the EQA in June 2018. 96% of ciprofloxacin MICs were reported within accepted deviations, as well as 88% for cefixime, 85% for ceftriaxone, 79% for penicillin and 70% for azithromycin. The use of interpretation standards and general laboratory procedures like agar base, incubation settings or the use of control strains strongly differed between laboratories. In statistical analysis, incubation time of cultures < 24 h was associated with correct measurements. Additionally, a 5% CO2 concentration was associated with correct results regarding azithromycin compared to 3%. CTREE analysis showed that incubation time, humidity and CO2 concentration had the greatest influence on the average deviation from consensus results. Conclusions In conclusion, we report the development of a protocol for N. gonorrhoeae antimicrobial susceptibility testing in Germany. While testing results were in accordance with the expected consensus results in 70–96%, depending on the antibiotic agent, laboratory methodology was heterogeneous and may significantly affect the testing quality. We therefore recommend the development of a standard operating procedure (SOP) for N. gonorrhoeae susceptibility testing in Germany.eng
dc.language.isoengnone
dc.publisherRobert Koch-Institut
dc.rights(CC BY 3.0 DE) Namensnennung 3.0 Deutschlandger
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/de/
dc.subject.ddc610 Medizin und Gesundheitnone
dc.titleExternal quality assessment (EQA) of Neisseria gonorrhoeae antimicrobial susceptibility testing in primary laboratories in Germanynone
dc.typearticle
dc.identifier.urnurn:nbn:de:0257-176904/13905-2
dc.identifier.doi10.1186/s12879-020-05234-w
dc.type.versionpublishedVersionnone
local.edoc.container-titleBMC Infectious Diseasesnone
local.edoc.container-issn1471-2334none
local.edoc.pages10none
local.edoc.type-nameZeitschriftenartikel
local.edoc.container-typeperiodical
local.edoc.container-type-nameZeitschrift
local.edoc.container-urlhttps://link.springer.com/journal/12879none
local.edoc.container-publisher-nameSpringer Naturenone
dc.description.versionPeer Reviewednone

Zur Kurzanzeige