Zur Kurzanzeige

2020-10-06Zeitschriftenartikel DOI: 10.3389/fmicb.2020.511674
Evaluation of MALDI-ToF Mass Spectrometry for Rapid Detection of Cereulide From Bacillus cereus Cultures
dc.contributor.authorDoellinger, Joerg
dc.contributor.authorSchneider, Andy
dc.contributor.authorStark, Timo D.
dc.contributor.authorEhling-Schulz, Monika
dc.contributor.authorLasch, Peter
dc.date.accessioned2026-10-01T12:31:40Z
dc.date.available2026-10-01T12:31:40Z
dc.date.issued2020-10-06none
dc.identifier.urihttp://edoc.rki.de/176904/13999
dc.description.abstractBacillus cereus plays an often unrecognized role in food borne diseases. Food poisoning caused by this pathogen is manifested by either diarrhea or emesis. Due to the relatively high prevalence of emetic toxin cereulide associated food poisoning, methods for simple and reliable detection of cereulide producing strains are of utmost importance. Recently, two different studies reported on the application of MALDI-ToF MS for either the differentiation of emetic and non-emetic strains of B. cereus or for direct detection of cereulide from bacterial colony smears. However, for implementation of cereulide detection using MALDI-ToF MS in routine microbiological diagnostics additional investigations on the sensitivity and specificity as well as on the fitting into common workflows for bacterial identification are needed. These aspects prompted us to investigate open issues and to test sample preparation methods, commonly used for microbial identification for their suitability to detect the emetic toxin from bacteria. Based on our experimental findings we propose a workflow that allows identification of B. cereus and sensitive detection of cereulide in parallel, using linear-mode MALDI-ToF MS equipment. The protocol was validated in a blinded study and is based on the well-established ethanol/formic acid extraction method. Cereulide is detected in the ethanol wash solution of samples identified as B. cereus as peaks at m/z 1175 and 1191. Peak position difference of 16 Th (Thomson) indicates detection of the sodium and potassium adducts of cereulide. This sample treatment offers possibilities for further characterization by more sophisticated LC-MS-based methods. In summary, the ease of use and the achieved level of analytical sensitivity as well as the wide-spread availability of MALDI-ToF MS equipment in clinical microbiological laboratories provides a promising tool to improve and to facilitate routine diagnostics of B. cereus associated food intoxications.eng
dc.language.isoengnone
dc.publisherRobert Koch-Institut
dc.rights(CC BY 3.0 DE) Namensnennung 3.0 Deutschlandger
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/de/
dc.subjectcereulideeng
dc.subjectB. cereuseng
dc.subjectMALDI-ToFeng
dc.subjectmass spectrometryeng
dc.subjecttoxin detectioneng
dc.subject.ddc610 Medizin und Gesundheitnone
dc.titleEvaluation of MALDI-ToF Mass Spectrometry for Rapid Detection of Cereulide From Bacillus cereus Culturesnone
dc.typearticle
dc.identifier.urnurn:nbn:de:0257-176904/13999-9
dc.identifier.doi10.3389/fmicb.2020.511674
dc.type.versionpublishedVersionnone
local.edoc.container-titleFrontiers in Microbiologynone
local.edoc.container-issn1664-302Xnone
local.edoc.pages12none
local.edoc.type-nameZeitschriftenartikel
local.edoc.container-typeperiodical
local.edoc.container-type-nameZeitschrift
local.edoc.container-urlhttps://www.frontiersin.org/journals/microbiologynone
local.edoc.container-publisher-nameFrontiers Media SA.none
local.edoc.container-volume11none
local.edoc.container-reportyear2020none
dc.description.versionPeer Reviewednone

Zur Kurzanzeige