Logo of Robert Koch InstituteLogo of Robert Koch Institute
Publication Server of Robert Koch Instituteedoc
de|en
View Item 
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
View Item 
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
2026-06-30Zeitschriftenartikel DOI: 10.1016/j.jhin.2026.05.040
Establishment of a standardized phase 2/step 2 method for virucidal surface disinfection: results of an interlaboratory ring trial (4-field test)
Roesch, Kira-Maria
Eggers, Maren
Bonner, N.
Brill, Florian Holger Hubert
Cavalleri, Michele
Gebel, Jürgen
Großjohann, B.
Konrat, Katharina
Lee, Cheng Shoou
Loeffert, Sophie Tiphaine
Mutters, Nico Tom
Paulmann, D.
Pitten, F.-A.
Rubrecht, C.
Schwebke, Ingeborg
Steinhauer, Katrin
Hildebradt, Claudia
Introduction Evaluating the virucidal efficacy of surface disinfectants under practical conditions with mechanical action remains a major challenge. Current standards primarily rely on suspension tests and carrier tests without mechanical action, whereas mechanical, surface-based methods are not yet sufficiently validated for virucidal testing. This methodological validation study reports the results of an interlaboratory ring trial on the 4-field test for viruses with hard water. The objective of the present study was to validate a practical test method aligned with European standards and to support the development of a new Work Item within the Working Group 1 of CEN Technical Committee 216 activities. Methods Thirteen European and international laboratories tested three human pathogenic model viruses – Adenovirus type 5, Modified Vaccinia Virus Ankara, and Murine Norovirus – on non-porous surfaces in the 4-field test using hard water. Virus recovery was assessed across multiple contact times, and repeatability and reproducibility were calculated according to ISO 13528. Results All viruses were reliably recovered on test field 1. The method was largely robust across laboratories, although variations in physical parameters affected interlaboratory consistency, underscoring the relevance of mechanically driven application factors. Conclusion The virucidal 4-field test demonstrates promising applicability as a phase 2/step 2 method and represents a valuable candidate for incorporation into future European standards. The method is particularly relevant for assessing ready-to-use wipes as virucidal efficacy depends on the combined effects of wipe material, released liquid, and mechanical action, which may substantially differ from results obtained in the absence of mechanical application. Representative-of-use validation methods are therefore essential for assessing disinfectant efficacy in hospitals, long-term care facilities, and public spaces.
Files in this item
Thumbnail
1-s2.0-S0195670126002240-main.pdf — Adobe PDF — 2.052 Mb
MD5: b23cea77195189512cc367f0e82657a5
Cite
BibTeX
EndNote
RIS
(CC BY 3.0 DE) Namensnennung 3.0 Deutschland(CC BY 3.0 DE) Namensnennung 3.0 Deutschland
Details
Terms of Use Imprint Policy Data Privacy Statement Contact

The Robert Koch Institute is a Federal Institute

within the portfolio of the Federal Ministry of Health

© Robert Koch Institute

All rights reserved unless explicitly granted.

 
DOI
10.1016/j.jhin.2026.05.040
Permanent URL
https://doi.org/10.1016/j.jhin.2026.05.040
HTML