Show simple item record

2026-06-30Zeitschriftenartikel DOI: 10.1016/j.jhin.2026.05.040
Establishment of a standardized phase 2/step 2 method for virucidal surface disinfection: results of an interlaboratory ring trial (4-field test)
dc.contributor.authorRoesch, Kira-Maria
dc.contributor.authorEggers, Maren
dc.contributor.authorBonner, N.
dc.contributor.authorBrill, Florian Holger Hubert
dc.contributor.authorCavalleri, Michele
dc.contributor.authorGebel, Jürgen
dc.contributor.authorGroßjohann, B.
dc.contributor.authorKonrat, Katharina
dc.contributor.authorLee, Cheng Shoou
dc.contributor.authorLoeffert, Sophie Tiphaine
dc.contributor.authorMutters, Nico Tom
dc.contributor.authorPaulmann, D.
dc.contributor.authorPitten, F.-A.
dc.contributor.authorRubrecht, C.
dc.contributor.authorSchwebke, Ingeborg
dc.contributor.authorSteinhauer, Katrin
dc.contributor.authorHildebradt, Claudia
dc.date.accessioned2026-08-31T15:36:50Z
dc.date.available2026-08-31T15:36:50Z
dc.date.issued2026-06-30none
dc.identifier.urihttp://edoc.rki.de/176904/13879
dc.description.abstractIntroduction Evaluating the virucidal efficacy of surface disinfectants under practical conditions with mechanical action remains a major challenge. Current standards primarily rely on suspension tests and carrier tests without mechanical action, whereas mechanical, surface-based methods are not yet sufficiently validated for virucidal testing. This methodological validation study reports the results of an interlaboratory ring trial on the 4-field test for viruses with hard water. The objective of the present study was to validate a practical test method aligned with European standards and to support the development of a new Work Item within the Working Group 1 of CEN Technical Committee 216 activities. Methods Thirteen European and international laboratories tested three human pathogenic model viruses – Adenovirus type 5, Modified Vaccinia Virus Ankara, and Murine Norovirus – on non-porous surfaces in the 4-field test using hard water. Virus recovery was assessed across multiple contact times, and repeatability and reproducibility were calculated according to ISO 13528. Results All viruses were reliably recovered on test field 1. The method was largely robust across laboratories, although variations in physical parameters affected interlaboratory consistency, underscoring the relevance of mechanically driven application factors. Conclusion The virucidal 4-field test demonstrates promising applicability as a phase 2/step 2 method and represents a valuable candidate for incorporation into future European standards. The method is particularly relevant for assessing ready-to-use wipes as virucidal efficacy depends on the combined effects of wipe material, released liquid, and mechanical action, which may substantially differ from results obtained in the absence of mechanical application. Representative-of-use validation methods are therefore essential for assessing disinfectant efficacy in hospitals, long-term care facilities, and public spaces.eng
dc.language.isoengnone
dc.publisherRobert Koch-Institut
dc.rights(CC BY 3.0 DE) Namensnennung 3.0 Deutschlandger
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/de/
dc.subject.ddc610 Medizin und Gesundheitnone
dc.titleEstablishment of a standardized phase 2/step 2 method for virucidal surface disinfection: results of an interlaboratory ring trial (4-field test)none
dc.typearticle
dc.identifier.urnurn:nbn:de:0257-176904/13879-6
dc.identifier.doi10.1016/j.jhin.2026.05.040
dc.type.versionpublishedVersionnone
local.edoc.container-titleJournal of Hospital Infectionnone
local.edoc.container-issn1532-2939none
local.edoc.pages11none
local.edoc.type-nameZeitschriftenartikel
local.edoc.container-typeperiodical
local.edoc.container-type-nameZeitschrift
local.edoc.container-urlhttps://www.sciencedirect.com/journal/journal-of-hospital-infectionnone
local.edoc.container-publisher-nameElseviernone
local.edoc.container-volume174none
local.edoc.container-reportyear2026none
local.edoc.container-firstpage301none
local.edoc.container-lastpage311none
dc.description.versionPeer Reviewednone

Show simple item record