Rapid and simultaneous detection of ricin, staphylococcal enterotoxin B and saxitoxin by chemiluminescence-based microarray immunoassay
dc.contributor.author | Szkola, A. | |
dc.contributor.author | Linares, E. M. | |
dc.contributor.author | Worbs, Sylvia | |
dc.contributor.author | Dorner, Brigitte | |
dc.contributor.author | Dietrich, R. | |
dc.contributor.author | Märtlbauer, E. | |
dc.contributor.author | Niessner, R. | |
dc.contributor.author | Seidel, Michael | |
dc.date.accessioned | 2018-05-07T18:25:26Z | |
dc.date.available | 2018-05-07T18:25:26Z | |
dc.date.created | 2015-08-19 | |
dc.date.issued | 2014-09-05 | none |
dc.identifier.other | http://edoc.rki.de/oa/articles/rezhPaIu6Wh/PDF/24mwkOek8p8pE.pdf | |
dc.identifier.uri | http://edoc.rki.de/176904/2119 | |
dc.description.abstract | Simultaneous detection of small and large molecules on microarray immunoassays is a challenge that limits some applications in multiplex analysis. This is the case for biosecurity, where fast, cheap and reliable simultaneous detection of proteotoxins and small toxins is needed. Two highly relevant proteotoxins, ricin (60 kDa) and bacterial toxin staphylococcal enterotoxin B (SEB, 30 kDa) and the small phycotoxin saxitoxin (STX, 0.3 kDa) are potential biological warfare agents and require an analytical tool for simultaneous detection. Proteotoxins are successfully detected by sandwich immunoassays, whereas competitive immunoassays are more suitable for small toxins ( | eng |
dc.language.iso | eng | |
dc.publisher | Robert Koch-Institut, Biologische Sicherheit | |
dc.subject.ddc | 610 Medizin | |
dc.title | Rapid and simultaneous detection of ricin, staphylococcal enterotoxin B and saxitoxin by chemiluminescence-based microarray immunoassay | |
dc.type | periodicalPart | |
dc.identifier.urn | urn:nbn:de:0257-10040495 | |
dc.identifier.doi | 10.1039/C4AN00345D | |
dc.identifier.doi | http://dx.doi.org/10.25646/2044 | |
local.edoc.container-title | Analyst | |
local.edoc.container-text | Szkola, A., Linares, E.M., Worbs, S., Dorner, B.G., Dietrich, R., Märtlbauer, E., Niessner, R., Seidel, M. Rapid and simultaneous detection of ricin, staphylococcal enterotoxin B and saxitoxin by chemiluminescence-based microarray immunoassay (2014) Analyst, 139 (22), pp. 5885-5892. | |
local.edoc.fp-subtype | Artikel | |
local.edoc.type-name | Zeitschriftenartikel | |
local.edoc.container-type | periodical | |
local.edoc.container-type-name | Zeitschrift | |
local.edoc.container-url | http://pubs.rsc.org/en/Content/ArticleLanding/2014/AN/C4AN00345D | |
local.edoc.container-publisher-name | Royal Society of Chemistry | |
local.edoc.container-volume | 139 | |
local.edoc.container-issue | 22 | |
local.edoc.container-year | 2014 |