Logo of Robert Koch InstituteLogo of Robert Koch Institute
Publication Server of Robert Koch Instituteedoc
de|en
View Item 
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
View Item 
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
2015-11-05Zeitschriftenartikel DOI: 10.2807/1560-7917.ES.2015.20.44.30053
Development and deployment of a rapid recombinase polymerase amplification Ebola virus detection assay in Guinea in 2015
Faye, Oumar
Faye, Ousmane
Soropogui, B.
Patel, Pranav
Wahed, Ahmed Abd El
Loucoubar, C.
Fall, G.
Kiory, D.
Magassouba, N.
Keita, S.
Kondé, M. K.
Diallo, A.
Koivogui, L.
Karlberg, H.
Mirazimi, Ali
Nentwich, O.
Piepenburg, O.
Niedrig, Matthias
Weidmann, Manfred
Sall, Amadou Alpha
In the absence of a vaccine or specific treatments for Ebola virus disease (EVD), early identification of cases is crucial for the control of EVD epidemics. We evaluated a new extraction kit (SpeedXtract (SE), Qiagen) on sera and swabs in combination with an improved diagnostic reverse transcription recombinase polymerase amplification assay for the detection of Ebola virus (EBOV-RT-RPA). The performance of combined extraction and detection was best for swabs. Sensitivity and specificity of the combined SE and EBOV-RT-RPA were tested in a mobile laboratory consisting of a mobile glovebox and a Diagnostics-in-a-Suitcase powered by a battery and solar panel, deployed to Matoto Conakry, Guinea as part of the reinforced surveillance strategy in April 2015 to reach the goal of zero cases. The EBOV-RT-RPA was evaluated in comparison to two real-time PCR assays. Of 928 post-mortem swabs, 120 tested positive, and the combined SE and EBOV-RT-RPA yielded a sensitivity and specificity of 100% in reference to one real-time RT-PCR assay. Another widely used real-time RT-PCR was much less sensitive than expected. Results were provided very fast within 30 to 60 min, and the field deployment of the mobile laboratory helped improve burial management and community engagement.
Files in this item
Thumbnail
23228fudliOW2.pdf — Adobe PDF — 975.1 Kb
MD5: 0e47cca50d53fcd2d4f4e9782f07b37b
Cite
BibTeX
EndNote
RIS
No license information
Details
Terms of Use Imprint Policy Data Privacy Statement Contact

The Robert Koch Institute is a Federal Institute

within the portfolio of the Federal Ministry of Health

© Robert Koch Institute

All rights reserved unless explicitly granted.

 
DOI
10.2807/1560-7917.ES.2015.20.44.30053
Permanent URL
https://doi.org/10.2807/1560-7917.ES.2015.20.44.30053
HTML
<a href="https://doi.org/10.2807/1560-7917.ES.2015.20.44.30053">https://doi.org/10.2807/1560-7917.ES.2015.20.44.30053</a>