Logo of Robert Koch InstituteLogo of Robert Koch Institute
Publication Server of Robert Koch Instituteedoc
de|en
View Item 
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
View Item 
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
2014-08-20Zeitschriftenartikel DOI: 10.1097/MBP.0000000000000081
Calibration of blood pressure data after replacement of the standard mercury sphygmomanometer by an oscillometric device and concurrent change of cuffs
Neuhauser, Hannelore
Ellert, Ute
Thamm, Michael
Adler, Carolin
Oscillometric blood pressure (BP) measurement devices are increasingly replacing standard mercury sphygmomanometers and generalizability of validation studies to other environments, for example, national survey environments, is assumed. We compared BP measurements according to two highly standardized German national survey BP protocols: a standard mercury sphygmomanometer and an oscillometric device, Datascope Accutorr Plus, each with specific manufacturer-provided cuffs and cuff-selection rules. A sample of 105 adults were subjected to alternate same-arm BP measurements according to the principles of the International Protocol revision 2010 for the validation of BP-measuring devices in adults of the European Society of Hypertension. In all, 315 BP measurement pairs were obtained. The mean systolic blood pressure (SBP) and diastolic blood pressure (DBP) were higher by the standard mercury old protocol and increased with BP, age, and pulse pressure, and were associated with the ratios of the cuff width to the arm circumference. The mean systolic difference (datascope new protocol−standard mercury old protocol) in participants with old protocol: for SBP
Files in this item
Thumbnail
27tOFlK6sA0dc.pdf — Adobe PDF — 184.1 Kb
MD5: 7e0cc45508c86aa4649fd4fd2555004f
Cite
BibTeX
EndNote
RIS
No license information
Details

Related Items

Show related Items with similar Title, Author, Creator or Subject.

  • 2014-04-01Zeitschriftenartikel
    Disagreement of the two oscillometric blood pressure measurement devices, Datascope Accutorr Plus and Omron HEM-705CP II, and bidirectional conversion of blood pressure values. 
    Adler, Carolin; Ellert, Ute; Neuhauser, Hannelore
    Objective(s): Oscillometric blood pressure (BP) measurement devices frequently replace the standard mercury sphygmomanometer. Comparisons of oscillometric devices are rare, but their agreement is important to ensure ...
  • 2007-05-20Zeitschriftenartikel
    Blutdruckmessung im Kinder- und Jugendgesundheitssurvey (KiGGS) 
    Methodik und erste Ergebnisse
    Neuhauser, Hannelore; Thamm, Michael
    Bluthochdruck ist einer der wichtigsten Risikofaktoren für Herz-Kreislauf-Erkrankungen und rangiert unter den führenden Ursachen für Morbidität und Mortalität weltweit. Hypertonie bei Kindern ist zwar selten, doch ist der ...
  • 2013-05-27Zeitschriftenartikel
    Blood pressure in Germany 2008–2011 
    Results of the German Health Interview and Examination Survey for Adults (DEGS1)
    Neuhauser, Hannelore; Thamm, Michael; Ellert, Ute
    High blood pressure is one of the most important risk factors for cardiovascular diseases and chronic kidney disease. It is a main determinant of morbidity and mortality in Germany. In the German Health Interview and ...
Terms of Use Imprint Policy Data Privacy Statement Contact

The Robert Koch Institute is a Federal Institute

within the portfolio of the Federal Ministry of Health

© Robert Koch Institute

All rights reserved unless explicitly granted.

 
DOI
10.1097/MBP.0000000000000081
Permanent URL
https://doi.org/10.1097/MBP.0000000000000081
HTML
<a href="https://doi.org/10.1097/MBP.0000000000000081">https://doi.org/10.1097/MBP.0000000000000081</a>