Logo of Robert Koch InstituteLogo of Robert Koch Institute
Publication Server of Robert Koch Instituteedoc
de|en
View Item 
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
View Item 
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
2016-01-12Zeitschriftenartikel DOI: 10.1016/j.ebiom.2016.01.008
Enabling Precision Medicine With Digital Case Classification at the Point-of-Care
Obermeier, Patrick
Muehlhans, Susann
Hoppe, Christian
Karsch, Katharina
Tief, Franziska
Chen, Xi
Conrad, Tim
Böttcher, Sindy
Diedrich, Sabine
Rath, Barbara
Infectious and inflammatory diseases of the central nervous system are difficult to identify early. Case definitions for aseptic meningitis, encephalitis, myelitis, and acute disseminated encephalomyelitis (ADEM) are available, but rarely put to use. The VACC-Tool (Vienna Vaccine Safety Initiative Automated Case Classification-Tool) is a mobile application enabling immediate case ascertainment based on consensus criteria at the point-of-care. The VACC-Tool was validated in a quality management program in collaboration with the Robert-Koch-Institute. Results were compared to ICD-10 coding and retrospective analysis of electronic health records using the same case criteria. Of 68,921 patients attending the emergency room in 10/2010–06/2013, 11,575 were hospitalized, with 521 eligible patients (mean age: 7.6 years) entering the quality management program. Using the VACC-Tool at the point-of-care, 180/521 cases were classified successfully and 194/521 ruled out with certainty. Of the 180 confirmed cases, 116 had been missed by ICD-10 coding, 38 misclassified. By retrospective application of the same case criteria, 33 cases were missed. Encephalitis and ADEM cases were most likely missed or misclassified. The VACC-Tool enables physicians to ask the right questions at the right time, thereby classifying cases consistently and accurately, facilitating translational research. Future applications will alert physicians when additional diagnostic procedures are required.
Files in this item
Thumbnail
2910H2Eobc5s.pdf — Adobe PDF — 442.9 Kb
MD5: a2546e5308e24e43d31def9907153800
Cite
BibTeX
EndNote
RIS
No license information
Details
Terms of Use Imprint Policy Data Privacy Statement Contact

The Robert Koch Institute is a Federal Institute

within the portfolio of the Federal Ministry of Health

© Robert Koch Institute

All rights reserved unless explicitly granted.

 
DOI
10.1016/j.ebiom.2016.01.008
Permanent URL
https://doi.org/10.1016/j.ebiom.2016.01.008
HTML
<a href="https://doi.org/10.1016/j.ebiom.2016.01.008">https://doi.org/10.1016/j.ebiom.2016.01.008</a>