Logo of Robert Koch InstituteLogo of Robert Koch Institute
Publication Server of Robert Koch Instituteedoc
de|en
View Item 
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
View Item 
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
  • edoc-Server Home
  • Artikel in Fachzeitschriften
  • Artikel in Fachzeitschriften
  • View Item
2019-07-23Zeitschriftenartikel
Comparison of VITEK 2, three different gradient strip tests and broth microdilution for detecting vanB-posotive Enterococcus faecium isolates with low vancomycin MICs
Klare, Ingo
Bender, Jennifer K.
Kriebel, Nancy
Hamprecht, Axel
Gatermann, Sören
Werner, Guido
Objectives In 2018, EUCAST issued a warning regarding unreliable results of gradient strip tests for confirming vancomycin resistance in enterococci. We compared the performance of various diagnostic standard and confirmatory tests to identify and determine vanB-type vancomycin resistance. Methods We analysed a collection of vanB-positive Enterococcus faecium isolates (n = 68) with low vancomycin MICs and compared the performance of VITEK® 2 (bioMérieux), broth microdilution and three gradient strip tests from different providers (Oxoid, Liofilchem and bioMérieux). For the latter we compared the standard procedure with a protocol with increased inoculum, a rich agar medium and a longer incubation time (‘macromethod’). Results The sensitivity of VITEK® 2 was 81% compared with 72% for broth microdilution and 61%–63% for the three gradient strip tests using standard conditions. The macromethod substantially improved the performance of all strip tests resulting in a sensitivity of 89%–96% after 48 h of incubation. Conclusions We recommend that EUCAST changes the present warning against the general use of MIC strips. When MIC strips are used to either exclude or confirm suspected vancomycin resistance in E. faecium, and a PCR is not available, the macromethod should be employed. For clinically relevant enterococci, where a rapid therapeutic decision is needed, a molecular test (e.g. PCR) should be favoured in order to save time and to further increase sensitivity.
Files in this item
Thumbnail
dkz310.pdf — Adobe PDF — 229.0 Kb
MD5: ec572dddcf254a8ca2debd2343e35b15
Cite
BibTeX
EndNote
RIS
(CC BY-NC 3.0 DE) Namensnennung - Nicht kommerziell 3.0 Deutschland(CC BY-NC 3.0 DE) Namensnennung - Nicht kommerziell 3.0 Deutschland(CC BY-NC 3.0 DE) Namensnennung - Nicht kommerziell 3.0 Deutschland
Details
Terms of Use Imprint Policy Data Privacy Statement Contact

The Robert Koch Institute is a Federal Institute

within the portfolio of the Federal Ministry of Health

© Robert Koch Institute

All rights reserved unless explicitly granted.